The IMT MAX-HD 2.0 is a high-definition, anthropomorphic QA phantom specifically designed for End-to-End SRS commissioning. MAX-HD 2.0 is an unrivalled SRS training resource providing QA for image acquisition from both CT and MR modalities, image fusion, multiple target simulation, IGRT localization, and dosimetric plan verification. MAX-HD 2.0 is an efficient tool for comprehensive End-to-End system testing.
Stereotactic Radiosurgery (SRS) involves high dose fractions delivered to tightly constrained treatment volumes, with sharp dose fall-off toward critical structures. The advent of MR-Guided treatment platforms presents unique challenges for performing initial commissioning of new systems, and routine End-To-End QA. MAX-HD 2.0 is the first SRS QA Phantom to provide Fully-Anthropomorphic, High-Definition imaging capability for IGRT QA with MR, CT, kV and MV modalities.
Cast from new proprietary materials, the entirety of MAX-HD's soft tissue anatomy is MR-Visible, providing truly comprehensive End-To-End SRS QA across MR-Guided and MR-Simulation systems.
MAX-HD 2.0 is an efficient tool for comprehensive End-to-End system testing. The anthropomorphic features include brain, vertebrae, sinus cavities, cortical and trabecular bone structure, larynx, trachea, and oral cavities.
Cast from new proprietary materials, the entirety of MAX-HD's soft tissue anatomy is MR-Visible, providing truly comprehensive End-To-End SRS QA across MR-Guided and MR-Simulation systems.
MAX-HD 2.0 is an efficient tool for comprehensive End-to-End system testing. The anthropomorphic features include brain, vertebrae, sinus cavities, cortical and trabecular bone structure, larynx, trachea, and oral cavities.
MAX-HD 2.0 features multiple dosimetric opportunities, including two 3D Film Target Inserts, Large Coronal Film Plane, Ion Chamber Measurement, and up to twenty OSLD point readings.
Key Features
- Real-World Multiple Met SRS QA
- Exquisite High-Definition MR Visibility
- Supports MR Treatment Planning
- MR/CT Fusion
- MR Distortion Analysis
- HyperArc Commissioning
- Full Anatomical Localization in both CT and MR
- Supports 6DOF QA
- No messy & inconsistent liquids
- No tools required for assembly
- Film + Ion Chamber + OSLD/TLD Dosimetry
- Rental Program Available
- Supports multiple AAPM TG SRS testing protocols including TG101 and TG135 for:
- Complete End-To-End Tests
- Winston-Lutz test
- Isocentric Verification
- Bony Anatomy Localization
- Laser Alignment
- Localization / Repositioning with Couch Shifts
- Patient Orientation / Image Transfer QA
- IGRT QA for MR, X-Ray and On-board kV and MV images, including CBCT
- MR/CT Image Fusion Multiple MET Dosimetry