RadWall-W | Area Radiation Monitor is an all-digital area radiation monitor covering a wide range of gamma and X-ray radiation and includes a large display and cable routing.
RadWall-W | Area Radiation Monitor is a next-generation, all-digital area radiation monitor that combines three functions in one:
- Alarm and display unit
- Built-in scintillation detector
- Self-healing and self-forming mesh network capable monitor
RadWall-W | Area Radiation Monitor uses a high-performance YSO scintillation crystal combined with a state-of-the-art SiPM (YSO+SiPM) and multi-voltage threshold (MVT) algorithm to detect a wide range of radiation doses.
RadWall-W | Area Radiation Monitor has high detection accuracy, high sensitivity, and fast response, as well as other significant advantages.
RadWall-W | Area Radiation Monitor communicates with a wireless radiation monitoring network for data management. Proportional, real-time detection and measurement provide meaningful readouts that focus on real-world applications.
The fast response and wide dose rate range maximize the safety of your team. The large HD LCD provides a clear indication of dose rate.
RadWall-W | Area Radiation Monitor can be used as a standalone Area Radiation Monitor, or multiple units can be combined to form a protected mesh network communicating via ZigBee IEEE standard.
RadWall-W | Area Radiation Monitor is an alarm and display unit (ADU), providing detection and measurement with an internal scintillation detector.
Forming the backbone of a scalable RadSafe Radiation Monitoring Solution, RadWall-W | Area Radiation Monitor includes the RadSuite Monitoring Software to accommodate applications of any size or complexity.
Technical Specifications
Detector |
YSO Scintillator + SiPM |
---|---|
Type of Radiation Detected |
Gamma, X-Ray |
Energy Range |
20 keV–10 MeV |
Dose Rate Range |
10 µrem/h–10 rem/h (0.1 µSv/h–100 mSv/h) |
Sensitivity |
40 cps/mrem/h (4 cps/µSv/h) (∝ Cs-137) |
Energy Response |
≤ ±15% (Cs-137) @ 60 keV–1.5 MeV, ≤ ±20% (Cs-137) @ 20 keV–60 keV, ≤ ±30% (Cs-137) @ 1.5 MeV–3 MeV, ≤ ±50% (Cs-137) @ 3 MeV–10 MeV |
Dose Rate Linearity |
≤ ±15% up to 10 rem/h (100 mSv/h) |
Accuracy |
±15% (Cs-137) |
Alarm Threshold |
User-set values for dose rate: 20 µrem/h–10 rem/h (0.2 µSv/h–100 mSv/h) |
Alert Options |
Audible (80 dB at 12 in ∕ 30 cm), Visual (LED and Display) |
Alarm Response Time |
< 6 s |
Overload Display |
Activation When > 10 rem/h (100 mSv/h), Overload indication up to 100 rem/h (1 Sv/h) |
Display Units |
rem, Sv, Gy, rad |
Communications |
ZigBee, RadSys 2.0 (Cloud-Based Software), RadSuite-Monitor (PC-Based Software) |
Power Supply |
AC 100–240 V ∕ 50–60 Hz (UL Certified), Rechargeable Lithium-Ion Battery |
Battery Life |
Typically 8 h in Background Field |
Display |
HD LCD |
Weight |
19.0 oz (540 g) |
Dimensions |
⌀ 6.89 × 1.97 in (⌀ 175 x 50 mm) |
Accessories |
IoT-Cloud (FCC ID: 2AC7P-113), UL Certified AC Adapter |
Initialization Time |
< 10 s |
Operating Temperature |
14–122 °F (-10–50 °C) |
Storage/Transport Temperature |
-4–158 °F (-20–70 °C) |
Relative Humidity |
≤ 90% (non-condensing) |
EMI/EMC |
Exceeds IEC 61526 Requirements |
FCC Compliance |
FCC Part 15 |
CE Compliance |
CE Certified |